Auto-Chemistry Analyzers CS-300
£37,700.00
– Fully automatic and discrete Auto-Chemistry Analyzer CS-300
– Throughput of 300T/H for photometry tests and 450T/H for ISE tests
– Supports colorimetry and turbidimetry with various analysis methods
– 115 sample positions including routine, STAT, calibration, and QC positions
– Automatic liquid level detection and collision protection for sample probes
– Innovative reagent disk design for reduced consumption and expanded test items
– Compatible with standard cups, blood tubes, and multi-specification tubes
– PC operating system with graphical analysis control software
– Real-time, daily, and monthly quality control tracking available
– Compact dimensions of 1060mm x 790mm x 1150mm and weight of 230kg
Auto-Chemistry Analyzer CS-300
Fully automatic discrete analyzer delivering 300 tests/hour for photometry and 450 tests/hour for ISE testing. Advanced optical system with holographic grating, intelligent sample handling, and comprehensive quality control for high-volume clinical laboratories.

Clinical overview
The Auto-Chemistry Analyzer CS-300 is a fully automatic, discrete analyzer engineered for high-throughput clinical chemistry laboratories. Featuring rear spectrophotometry with holographic concave flat-field grating and cluster-optical path technology, the CS-300 delivers super-micro volume detection of reaction solutions with exceptional accuracy and reproducibility. The system supports multiple test principles including colorimetry, turbidimetry, end-point, kinetics, and fixed-time analysis with single/double wavelength detection and flexible reagent configurations.
With intelligent sample handling, automatic liquid level detection, collision protection, and a sophisticated reagent disk design that minimizes consumption while expanding test capacity, the CS-300 optimizes laboratory workflow and operational efficiency. The system accommodates standard cups, original blood tubes, and multi-specification tubes, providing flexibility for diverse specimen types and laboratory protocols.
Key features & surgeon benefits
Advanced Spectrophotometry
- Holographic concave flat-field grating with cluster-optical path
- Super-micro volume detection for enhanced sensitivity
- Wavelength range 340–800 nm with photo-diode LED array detection
Intelligent Probe Technology
- 60 nm polished probe with automatic liquid level detection
- Collision protection reduces probe contamination and maintenance
- Compatible with standard cups, blood tubes, and multi-specification tubes (Φ12–16 mm)
High-Volume Capacity
- 300 tests/hour for photometry; 450 tests/hour for ISE testing
- 115 sample positions with STAT priority and dedicated calibration/QC zones
- Flexible batch input for routine, STAT, and special protocols
Comprehensive QC & Connectivity
- Real-time, daily, and monthly QC tracking with out-of-control alarming
- LIS interface with TCP/IP and RS-232C connectivity
- Remote maintenance support and user-defined reporting formats
Technical specifications
| Equipment Type | Fully automatic, discrete, STAT priority |
|---|---|
| Throughput | 300 T/H (photometry); 450 T/H (ISE) |
| Test Principles | Colorimetry, turbidimetry, end-point, kinetics, fixed-time |
| Analysis Methods | Single/double wavelength; 1–2 multiple reagent items; linear and non-linear calibration |
| Sample Positions | 115 total (50 routine, 20 STAT, 34 calibration, 8 QC, 3 detergent) |
| Sample Volume | 2–35 μL (0.1 μL stepping) |
| Reagent Volume | R1: 10–350 μL; R2: 10–200 μL (1 μL stepping) |
| Sample Types | Standard cups, original blood tubes, multi-specification tubes (Φ12–16 mm × 25–100 mm) |
| Reaction Cuvettes | 120 positions, optical plastic |
| Total Reaction Volume | 150–450 μL (1 μL stepping) |
| Reaction Temperature | 37°C with circulating water control |
| Optical System | 20W/12V halogen lamp; grating photometer; rear spectrometer; wavelengths 340–800 nm |
| Detector | Photo-diode LED array |
| Calibration Methods | 1-point linear, 2-point linear, multi-point linear, non-linear |
| QC Tracking | Real-time, daily, monthly QC with automatic K-value trend description |
| Operating System | Windows XP with graphical analysis control software (English) |
| Connectivity | TCP/IP network, standard RS-232C; LIS interface; remote maintenance |
| Dimensions | 1060 mm (W) × 790 mm (D) × 1150 mm (H) |
| Weight | 230 kg |
| Power Supply | AC 220V ±22V, 50/60 Hz; 1.5 kVA |
| Warranty | 2 Year Manufacturer Warranty |
Standard instrument composition
| Item | Description | Qty |
|---|---|---|
| Main Analyzer Unit | Fully automatic discrete chemistry analyzer with integrated optical system, sample handling, and reaction modules | 1 |
| Reagent Disk | Innovative design with reduced consumption and expanded test item capacity | 1 |
| Sample Disk | Multi-function sample disk compatible with standard cups, blood tubes, and multi-specification tubes | 1 |
| Reaction Cuvette Carousel | 120-position optical plastic cuvette holder with constant temperature control | 1 |
| Waste Liquid Container | Integrated wastewater treatment with concentrated waste level alarming | 1 |
| Control Software | Graphical analysis control software (Windows XP, English version) with LIS interface | 1 |
| Power Supply & Cables | AC power cord and network/serial connectivity cables | 1 |
| Documentation | User manual, technical specifications, and maintenance guide | 1 |
Get in touch for pricing & availability
Contact our clinical laboratory equipment specialists to discuss the CS-300’s integration into your facility, pricing, delivery timelines, and customisation options.
Email: info@neuvar.co.uk