Bought this for the theatre and the value at this price point is hard to beat. It feels solid and properly engineered. Would order again without hesitation.
Dr. Sven Wright, Orthopaedic SurgeonVerified buyerJun 13, 2026

- Fully automatic and discrete Auto-Chemistry Analyzer CS-300
- Throughput of 300T/H for photometry tests and 450T/H for ISE tests
- Supports colorimetry and turbidimetry with various analysis methods
- 115 sample positions including routine, STAT, calibration, and QC positions
- Automatic liquid level detection and collision protection for sample probes
- Innovative reagent disk design for reduced consumption and expanded test items
- Compatible with standard cups, blood tubes, and multi-specification tubes
- PC operating system with graphical analysis control software
- Real-time, daily, and monthly quality control tracking available
- Compact dimensions of 1060mm x 790mm x 1150mm and weight of 230kg
Fully automatic discrete analyzer delivering 300 tests/hour for photometry and 450 tests/hour for ISE testing. Advanced optical system with holographic grating, intelligent sample handling, and comprehensive quality control for high-volume clinical laboratories.
The Auto-Chemistry Analyzer CS-300 is a fully automatic, discrete analyzer engineered for high-throughput clinical chemistry laboratories. Featuring rear spectrophotometry with holographic concave flat-field grating and cluster-optical path technology, the CS-300 delivers super-micro volume detection of reaction solutions with exceptional accuracy and reproducibility. The system supports multiple test principles including colorimetry, turbidimetry, end-point, kinetics, and fixed-time analysis with single/double wavelength detection and flexible reagent configurations.
With intelligent sample handling, automatic liquid level detection, collision protection, and a sophisticated reagent disk design that minimizes consumption while expanding test capacity, the CS-300 optimizes laboratory workflow and operational efficiency. The system accommodates standard cups, original blood tubes, and multi-specification tubes, providing flexibility for diverse specimen types and laboratory protocols.
| Equipment Type | Fully automatic, discrete, STAT priority |
|---|---|
| Throughput | 300 T/H (photometry); 450 T/H (ISE) |
| Test Principles | Colorimetry, turbidimetry, end-point, kinetics, fixed-time |
| Analysis Methods | Single/double wavelength; 1–2 multiple reagent items; linear and non-linear calibration |
| Sample Positions | 115 total (50 routine, 20 STAT, 34 calibration, 8 QC, 3 detergent) |
| Sample Volume | 2–35 μL (0.1 μL stepping) |
| Reagent Volume | R1: 10–350 μL; R2: 10–200 μL (1 μL stepping) |
| Sample Types | Standard cups, original blood tubes, multi-specification tubes (Φ12–16 mm × 25–100 mm) |
| Reaction Cuvettes | 120 positions, optical plastic |
| Total Reaction Volume | 150–450 μL (1 μL stepping) |
| Reaction Temperature | 37°C with circulating water control |
| Optical System | 20W/12V halogen lamp; grating photometer; rear spectrometer; wavelengths 340–800 nm |
| Detector | Photo-diode LED array |
| Calibration Methods | 1-point linear, 2-point linear, multi-point linear, non-linear |
| QC Tracking | Real-time, daily, monthly QC with automatic K-value trend description |
| Operating System | Windows XP with graphical analysis control software (English) |
| Connectivity | TCP/IP network, standard RS-232C; LIS interface; remote maintenance |
| Dimensions | 1060 mm (W) × 790 mm (D) × 1150 mm (H) |
| Weight | 230 kg |
| Power Supply | AC 110V/220V ±22V, 50/60 Hz; 1.5 kVA |
| Warranty | 2 Year Manufacturer Warranty |
| Item | Description | Qty |
|---|---|---|
| Main Analyzer Unit | Fully automatic discrete chemistry analyzer with integrated optical system, sample handling, and reaction modules | 1 |
| Reagent Disk | Innovative design with reduced consumption and expanded test item capacity | 1 |
| Sample Disk | Multi-function sample disk compatible with standard cups, blood tubes, and multi-specification tubes | 1 |
| Reaction Cuvette Carousel | 120-position optical plastic cuvette holder with constant temperature control | 1 |
| Waste Liquid Container | Integrated wastewater treatment with concentrated waste level alarming | 1 |
| Control Software | Graphical analysis control software (Windows XP, English version) with LIS interface | 1 |
| Power Supply & Cables | AC power cord and network/serial connectivity cables | 1 |
| Documentation | User manual, technical specifications, and maintenance guide | 1 |
Contact our clinical laboratory equipment specialists to discuss the CS-300's integration into your facility, pricing, delivery timelines, and customisation options.
Available on request
The full spec + documentation pack for this device ships ahead of purchase on request. A sales engineer responds within one business day.
Configuration sheet
Sizes and dimensions, material and finish, compatible instruments and screw references, what ships in the set, lead time and warranty — all in one specification sheet, sent within one business day.
Documents & downloads
This device's IFU, CE Declaration of Conformity, ISO 13485 certificate and (where applicable) FDA 510(k) clearance ship with the order. Reach out below for the pack ahead of purchase.
Get in touch
Our clinical sales team will scope quantities, voltage, accessories and regulatory paperwork — usually within one business day.
Bought this for the theatre and the value at this price point is hard to beat. It feels solid and properly engineered. Would order again without hesitation.
Dr. Sven Wright, Orthopaedic SurgeonVerified buyerJun 13, 2026
Bought this for the clinic and it integrates neatly with the kit we already run. Delivery was quick and everything arrived well-packaged. Solid purchase overall.
Thomas Martin, MD, FRCSVerified buyerMar 22, 2025
Been putting it through daily use in the surgical unit and setup was straightforward with clear documentation. It feels solid and properly engineered. A dependable choice for any surgical unit.
Robert Hughes, Nurse ManagerJan 17, 2026

- Advanced Biochemistry Analyzer NEUBA07 for accurate diagnostic testing. - High-resolution 5.7” touch screen LCD display for user-friendly operation. - Supports keyboard and mouse through USB interfaces for enhanced functionality. - Micro dimensions flow cell with precise temperature control ensures reliable results. - Real-time reaction curve monitoring for timely detection of abnormal conditions. - Capable of storing up to 20,000 sample results with result correction features. - Multiple output formats including comprehensive patient reports available. - Integrated quality control functionality with data statistics and searching capabilities. - RS-232 intercommunication and optional Lead-Workstation biochemistry analyzing software for enhanced performance. - Compact design (430x330x140mm) and lightweight (7.0kg) for easy integration into laboratory settings.

- Advanced semi-automatic chemistry analyzer for precise testing. - Supports multiple analytical modes: kinetic, fixed time, end-point, and absorbance. - 7 standard filters (340-630nm) with one optional filter for versatile testing. - Full open reagent system with unlimited programming options for test items. - User-friendly interface featuring voice prompts and Windows operation support. - Real-time graph display and printing capabilities for easy result interpretation. - Energy-efficient lamp saving feature extends light source life beyond 2000 hours. - Large data storage capacity, capable of storing up to 1,000,000 results. - PELTIER temperature control system for consistent testing at various temperatures. - CE certified for quality assurance and compliance in medical settings.

- User-friendly Windows operating system with mouse control - Large 7" color LCD display for easy reading - Flexible reagent open system supporting both flow cell and cuvette modes - Multiple analytical modes: kinetic, fixed time, dichromatic end point - Real-time curve monitoring for enhanced result reliability - Memory capacity for up to 200 test protocols and 3000 test results - Robust quality control features including West guard Multi-rule - Auto power-on self-check to ensure operational readiness - Easy maintenance; no service engineers needed for lamp or tube changes - Compact design with a weight of 8kg and dimensions of 460x330x190 mm

- User-friendly Windows operating system with built-in mouse and large color LCD - Versatile reagent system supporting flow cell and cuvette modes - Multiple analytical modes including kinetic and fixed time - Real-time curve monitoring for enhanced test result reliability - Large memory for up to 200 test protocols and 3000 test results - Comprehensive QC functions including Westguard Multi-rule and Levey Jennings plot - Auto power on self-check for convenient operation - Compact design allows for easy user maintenance - Multi-language software and customizable OEM options available - Various result output formats including patient comprehensive reports

- Fully automatic, discrete operation with STAT priority - High throughput: 400 tests/hour for photometry, 600 tests/hour for ISE - Advanced optical system with a wavelength range of 340nm to 800nm - 115 sample positions including routine, STAT, calibration, and QC - Versatile reagent probe with liquid level detection and collision protection - User-defined batch input for efficient data handling - Supports multiple analysis methods: colorimetry, turbidimetry, and ISE - Automatic quality control and real-time alarming for out-of-control samples - Compact design with dimensions of 1060mm x 790mm x 1150mm and weight of 300kg - Compatible with Windows XP and features graphical operating software

- Advanced post position semi-conductor for efficient heat management - Automatic liquid level detection for optimal probe depth - 8 stops and 12 stops rinsing with warm water for thorough cleaning - Long-life halogen light source with minimal signal attenuation - Random access, fully automatic, discrete system design - High throughput rates: 800 tests/hour for colorimetric, 400 tests/hour for ISE - Multiple analysis methods: end-point, kinetics, and fixed-time - Dual independent mixers for sufficient reaction mixing - Comprehensive temperature control with precise incubation at 37°C - Up to 140 sample positions and support for multiple sample tubes and cups

- Advanced post position semi-conductor for stable temperature control - Automatic liquid level detection for optimal probe immersion - Efficient rinsing system with 8 or 12 stops using warm water - Long-life halogen lamp light source for consistent performance - High throughput: 900 tests/hour for colorimetric, 1260 tests/hour for ISE - Multiple analysis methods: end-point, kinetics, and fixed-time - Independently functioning sample and reagent probes with clot detection - Precise temperature control at 37°C ± 0.1°C for reactions - Large capacity with 140 sample positions and 132 reagent positions - Flexible sample and reagent volumes for various testing needs