Urinalysis Hybrid Analyzer Machine FUS-2000
£8,321.50£10,900.00 (-24%)
– Advanced Urinalysis Hybrid Analyzer Machine FUS-2000
– Processes a variety of urine samples with high throughput (120 T/H for formed elements, 240 T/H for chemistry)
– Supports sample loading of 50/270 samples for increased efficiency
– Equipped with a user-friendly Windows 10 operating system and bidirectional LIS/HIS connectivity
– Large memory capacity for up to 100,000 records
– External output options including RS-232, USB, and Net Port
– Compact dimensions: 688mm x 779mm x 584mm (L x W x H)
– Comprehensive urine analysis parameters including protein, glucose, and blood
– Utilizes photoelectric colorimetry and flow imaging technology for accurate results
– Compatible with external printers for easy reporting of results
Urinalysis Hybrid Analyzer Machine FUS-2000
Advanced hybrid analyzer combining chemistry and formed elements analysis in a single platform. Delivers high-throughput processing with dual-channel capability, comprehensive parameter coverage, and seamless LIS/HIS integration for modern clinical laboratories.
Clinical overview
The FUS-2000 is a dual-channel urinalysis analyzer engineered for high-volume clinical laboratories. It combines photoelectric colorimetry for chemistry analysis with flow imaging technology for formed elements detection, eliminating the need for separate instruments and streamlining workflow. The system processes 240 samples per hour for chemistry and 120 samples per hour for formed elements, with flexible sample loading (50 or 270 samples) to accommodate varying laboratory volumes.
Equipped with Windows 10 operating system and bidirectional LIS/HIS connectivity, the FUS-2000 integrates seamlessly into existing laboratory information systems. Large memory capacity (100,000+ records), external output options (RS-232, USB, Net Port), and compatibility with external printers ensure comprehensive reporting and data management capabilities essential for modern diagnostic laboratories.
Key features & surgeon benefits
Dual-Channel High-Speed Processing
- 240 T/H for chemistry analysis
- 120 T/H for formed elements
- Flexible sample loading (50 or 270 samples)
Integrated Laboratory Solution
- Bidirectional LIS/HIS connectivity
- Windows 10 operating system
- External printer compatibility for easy reporting
Comprehensive Parameter Analysis
- 16 chemistry parameters including protein, glucose, blood
- 11 formed elements parameters (RBC, WBC, casts, bacteria, yeast)
- Research parameters for advanced diagnostics
Precision Detection Methods
- Photoelectric colorimetry (525–660 nm wavelength)
- Flow imaging technique for morphology
- Accurate results with minimal sample volume
Technical specifications
| Indications | Routine urinalysis, urine chemistry, formed elements detection |
|---|---|
| Sample types | Urine |
| Sample loading | 50/270 samples (optional) |
| Throughput (chemistry) | 240 T/H |
| Throughput (formed elements) | 120 T/H |
| Sample volume (chemistry) | Minimum 2 mL; aspiration ~1.2 mL |
| Sample volume (formed elements) | Minimum 3 mL; aspiration ~2.0 mL |
| Operating temperature | 15–35°C |
| Humidity | ≤80% |
| Dimensions | 688 mm (L) × 779 mm (W) × 584 mm (H) |
| Weight | 82 kg (114 kg with reclaiming tray) |
| Power supply | 100–240 V, 50/60 Hz |
| Memory capacity | 100,000+ records |
| External output | RS-232, USB, Net Port |
| Operating system | Windows 10 |
| LIS/HIS connectivity | Bidirectional |
| Warranty | 2 Year Manufacturer Warranty |
Chemistry analysis parameters
| Parameter | Detection Method |
|---|---|
| Urobilinogen | Photoelectric colorimetry |
| Bilirubin | Photoelectric colorimetry |
| Ketones | Photoelectric colorimetry |
| Blood | Photoelectric colorimetry |
| Protein | Photoelectric colorimetry |
| Nitrite | Photoelectric colorimetry |
| Leucocyte | Photoelectric colorimetry |
| Glucose | Photoelectric colorimetry |
| pH | Photoelectric colorimetry |
| Creatinine | Photoelectric colorimetry |
| Calcium | Photoelectric colorimetry |
| Vitamin C | Photoelectric colorimetry |
| Microalbumin | Photoelectric colorimetry |
| Specific gravity | Photoelectric colorimetry |
| Color | Visual assessment |
| Turbidity | Visual assessment |
Formed elements analysis parameters
| Parameter | Detection Method |
|---|---|
| Red blood cells (RBC) | Flow imaging technique |
| White blood cells (WBC) | Flow imaging technique |
| Squamous epithelial cells | Flow imaging technique |
| Non-squamous epithelial cells | Flow imaging technique |
| Hyaline casts | Flow imaging technique |
| Unclassified casts | Flow imaging technique |
| Mucus | Flow imaging technique |
| Bacteria | Flow imaging technique |
| Yeast | Flow imaging technique |
| WBC clumps | Flow imaging technique |
| Sperm | Flow imaging technique |
| RBC information (research) | Flow imaging technique |
Standard instrument composition
| Item | Description | Qty |
|---|---|---|
| Main analyzer unit | FUS-2000 hybrid urinalysis analyzer with dual-channel processing | 1 |
| Sample loader | Automated sample loading carousel (50 or 270 samples) | 1 |
| Reagent cartridge | Chemistry test strip cartridge (up to 200 strips) | As applicable |
| Waste container | Reclaiming tray for sample waste | 1 |
| Power cable | 100–240 V, 50/60 Hz compatible | 1 |
| Data cable | RS-232, USB, and network connectivity cables | 1 set |
| User manual | Comprehensive operating and maintenance documentation | 1 |
Get in touch for pricing & availability
Contact our sales team to discuss the FUS-2000 specifications, sample configurations, and delivery timelines. We provide comprehensive support and customisation options for laboratory integration.
Email: info@neuvar.co.uk













