KT88-3200 Digital Brain Electric Activity Mapping
£1,990.00
– Collects EEG signals using electrodes for comprehensive brain activity analysis
– Integrated amplification and A/D transformation for accurate electroencephalogram display
– Supports international 10/20 electrode placement and allows lead changes during replay
– Continuous recording capability of up to 24 hours with automatic calibration system
– Powerful playback features with adjustable amplitude and display speed
– Advanced digital filter system for customized analysis of EEG signals
– EEG signal clipping for detailed analysis and parameter extraction
– User-defined event marking with color coding for simplified waveform retrieval
– Automatic analysis for power spectrum and pathologic wave detection
– Versatile data management with export/import functions and various file formats
– Optional video recording feature for synchronized waveform and visual documentation
KT88-3200 Digital Brain Electric Activity Mapping
Comprehensive EEG signal acquisition and analysis system with integrated amplification, real-time processing, and advanced diagnostic capabilities. Supports international 10/20 electrode placement standards with continuous recording up to 24 hours and powerful automated analysis for epilepsy, intracranial inflammation, cerebrovascular disease, and brain tumor detection.
Clinical overview
The KT88-3200 is a professional-grade digital electroencephalography system designed for comprehensive brain electrical activity mapping and analysis. It collects EEG signals via electrodes and processes them through integrated bioelectric amplification and analog-to-digital transformation to generate high-fidelity electroencephalograms with color-depth visualization. The system is applicable for diagnosing epilepsy, intracranial inflammation, cerebrovascular diseases, and brain tumors, making it an essential tool for neurology departments, epilepsy centers, and comprehensive diagnostic facilities.
With continuous recording capability up to 24 hours, automatic calibration, and powerful playback features, the KT88-3200 enables clinicians to capture extended monitoring sessions and perform detailed retrospective analysis. The system supports international 10/20 electrode placement standards with flexible lead configuration during both acquisition and replay, accommodating diverse clinical protocols and patient populations.
Key features & surgeon benefits
Superior EEG Capture
- International 10/20 electrode placement standard with flexible lead reconfiguration
- Bioelectric amplifier with integrated A/D transformation for accurate signal fidelity
- Continuous recording up to 24 hours with automatic full-system calibration
Advanced Diagnostic Tools
- Powerful playback with adjustable amplitude and display speed for detailed waveform review
- Digital filter system with customizable window types for signal optimization
- Electronic frequency ruler and partial enlargement window for precise measurements
Intelligent Detection
- Automatic power spectrum analysis and pathologic wave detection
- EEG signal clipping and multi-segment parameter extraction
- Event marking with color coding for rapid waveform retrieval by clinical event
Comprehensive Documentation
- Export/import functions with EDF and BDF format support for data exchange
- Optional USB video recording with synchronized waveform and visual documentation
- Professional isolation transformer with dual power supply and optoelectronic transmission for safety
Technical specifications
| Indications | Epilepsy, intracranial inflammation, cerebrovascular diseases, brain tumors |
|---|---|
| Electrode System | International 10/20 standard with configurable lead combinations |
| Recording Duration | Continuous up to 24 hours |
| Amplification | Integrated bioelectric amplifier with automatic calibration |
| Data Transmission | USB interface with optoelectronic isolation |
| File Formats | EDF, BDF, proprietary formats with export/import capability |
| Optional Features | USB video recording, SpO2 monitoring, multifunctional flash stimulator |
| Warranty | 2 Year Manufacturer Warranty |
Standard instrument composition
| Item | Description | Qty |
|---|---|---|
| Main EEG Unit | KT88-3200 Digital Brain Electric Activity Mapping System with integrated amplifier and processor | 1 |
| Electrode Set | Complete 10/20 standard electrode placement system with leads | 1 |
| Bioamplifier Module | Integrated signal amplification and A/D conversion unit | 1 |
| Calibration System | Automatic full-system calibration module | 1 |
| USB Interface Cable | Data transmission and power isolation cable | 1 |
| Flash Stimulator | Multifunctional USB-interface stimulator with manual/automatic control | 1 |
| Software Suite | Comprehensive EEG acquisition, analysis, and reporting software | 1 |