KT88-3200 Digital Brain Electric Activity Mapping

£1,990.00

In stock

– Collects EEG signals using electrodes for comprehensive brain activity analysis
– Integrated amplification and A/D transformation for accurate electroencephalogram display
– Supports international 10/20 electrode placement and allows lead changes during replay
– Continuous recording capability of up to 24 hours with automatic calibration system
– Powerful playback features with adjustable amplitude and display speed
– Advanced digital filter system for customized analysis of EEG signals
– EEG signal clipping for detailed analysis and parameter extraction
– User-defined event marking with color coding for simplified waveform retrieval
– Automatic analysis for power spectrum and pathologic wave detection
– Versatile data management with export/import functions and various file formats
– Optional video recording feature for synchronized waveform and visual documentation

SKU: 74c69a6053b9 Categories: , Brand:
Clinical & Diagnostic Devices

KT88-3200 Digital Brain Electric Activity Mapping

Comprehensive EEG signal acquisition and analysis system with integrated amplification, real-time processing, and advanced diagnostic capabilities. Supports international 10/20 electrode placement standards with continuous recording up to 24 hours and powerful automated analysis for epilepsy, intracranial inflammation, cerebrovascular disease, and brain tumor detection.

Indication(s): Epilepsy, intracranial inflammation, cerebrovascular diseases, brain tumors
Range / sizes: Standard 10/20 electrode system with configurable lead combinations
Sterilisation: As applicable
2 Year Warranty
Lifetime Support
Fast Delivery
USB Interface
Ordering Ref.
74c69a6053b9
ConfigurationStandard 10/20 System
MaterialMedical-grade electrodes & bioamplifier
ApplicationNeurological diagnostics
Optional video recording and SpO2 monitoring available. Customizable lead configurations and analysis parameters to meet institutional requirements.

Clinical overview

The KT88-3200 is a professional-grade digital electroencephalography system designed for comprehensive brain electrical activity mapping and analysis. It collects EEG signals via electrodes and processes them through integrated bioelectric amplification and analog-to-digital transformation to generate high-fidelity electroencephalograms with color-depth visualization. The system is applicable for diagnosing epilepsy, intracranial inflammation, cerebrovascular diseases, and brain tumors, making it an essential tool for neurology departments, epilepsy centers, and comprehensive diagnostic facilities.

With continuous recording capability up to 24 hours, automatic calibration, and powerful playback features, the KT88-3200 enables clinicians to capture extended monitoring sessions and perform detailed retrospective analysis. The system supports international 10/20 electrode placement standards with flexible lead configuration during both acquisition and replay, accommodating diverse clinical protocols and patient populations.

Key features & surgeon benefits

Signal Acquisition

Superior EEG Capture

  • International 10/20 electrode placement standard with flexible lead reconfiguration
  • Bioelectric amplifier with integrated A/D transformation for accurate signal fidelity
  • Continuous recording up to 24 hours with automatic full-system calibration
Analysis & Visualization

Advanced Diagnostic Tools

  • Powerful playback with adjustable amplitude and display speed for detailed waveform review
  • Digital filter system with customizable window types for signal optimization
  • Electronic frequency ruler and partial enlargement window for precise measurements
Automated Processing

Intelligent Detection

  • Automatic power spectrum analysis and pathologic wave detection
  • EEG signal clipping and multi-segment parameter extraction
  • Event marking with color coding for rapid waveform retrieval by clinical event
Data Management

Comprehensive Documentation

  • Export/import functions with EDF and BDF format support for data exchange
  • Optional USB video recording with synchronized waveform and visual documentation
  • Professional isolation transformer with dual power supply and optoelectronic transmission for safety

Technical specifications

Indications Epilepsy, intracranial inflammation, cerebrovascular diseases, brain tumors
Electrode System International 10/20 standard with configurable lead combinations
Recording Duration Continuous up to 24 hours
Amplification Integrated bioelectric amplifier with automatic calibration
Data Transmission USB interface with optoelectronic isolation
File Formats EDF, BDF, proprietary formats with export/import capability
Optional Features USB video recording, SpO2 monitoring, multifunctional flash stimulator
Warranty 2 Year Manufacturer Warranty

Standard instrument composition

Item Description Qty
Main EEG Unit KT88-3200 Digital Brain Electric Activity Mapping System with integrated amplifier and processor 1
Electrode Set Complete 10/20 standard electrode placement system with leads 1
Bioamplifier Module Integrated signal amplification and A/D conversion unit 1
Calibration System Automatic full-system calibration module 1
USB Interface Cable Data transmission and power isolation cable 1
Flash Stimulator Multifunctional USB-interface stimulator with manual/automatic control 1
Software Suite Comprehensive EEG acquisition, analysis, and reporting software 1

Get in touch for pricing & availability

Contact our clinical specialists to discuss system configuration, pricing, and delivery options for the KT88-3200. We provide comprehensive support and customization to meet your facility’s diagnostic requirements.

Phone: +44(7463)676084
Email: info@neuvar.co.uk

Request a Quote

KT88-3200 Digital Brain Electric Activity Mapping

SKU: 74c69a6053b9

    Menu

    KT88-3200 Digital Brain Electric Activity Mapping

    KT88-3200 Digital Brain Electric Activity Mapping

    £1,990.00

    Add to cart